Latex anaphylaxis caused by a Swan-Ganz catheter

Intern Med. 2011;50(4):355-7. doi: 10.2169/internalmedicine.50.4742. Epub 2011 Feb 15.

Abstract

A 78-year-old woman visited the division of cardiovascular disease in our hospital. She underwent a cardiac catheter examination, and a Swan-Ganz catheter was inserted. Several minutes later, she developed anaphylactic shock. She had no past history of latex allergy, but did have a banana allergy. Skin prick tests showed a positive reaction to an extract of latex gloves and an extract of the balloon of a Swan-Ganz catheter. Anaphylactic shock caused by the latex balloon of a Swan-Ganz catheter was diagnosed. It is necessary to pay attention to not only latex allergy but also fruit allergies with a cross-reactivity to latex.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Anaphylaxis / etiology*
  • Catheterization, Swan-Ganz / adverse effects*
  • Catheterization, Swan-Ganz / instrumentation
  • Catheters / adverse effects
  • Cross Reactions
  • Female
  • Humans
  • Latex / adverse effects
  • Latex / immunology
  • Latex Hypersensitivity / diagnosis
  • Latex Hypersensitivity / etiology*
  • Musa / adverse effects
  • Musa / immunology
  • Skin Tests