Individualised dialysate temperature improves intradialytic haemodynamics and abrogates haemodialysis-induced myocardial stunning, without compromising tolerability

Blood Purif. 2011;32(1):63-8. doi: 10.1159/000324199. Epub 2011 Feb 24.

Abstract

Background/aims: Haemodialysis-induced myocardial stunning is associated with intradialytic hypotension, increased likelihood of cardiovascular events and death. Dialysis at 35°C reduces stunning, but adverse thermal symptoms limit technique adoption. This study investigated whether individualised body temperature dialysis improves haemodynamic stability and abrogates stunning.

Methods: Randomised crossover study of 11 patients compared LV regional wall motion abnormalities (RWMAs) at 37°C (HD(37)) and body temperature ('individualised', HD(ind)). Regional systolic function was quantitatively assessed by echocardiography. Haemodynamics were assessed using continuous pulse wave analysis. Thermal symptoms were scored by questionnaire.

Results: Mean predialysis body temperature was 36.0 ± 0.1°C. Mean number of peak stress RWMAs per patient was lower with HD(ind) (3.9 ± 1.4 vs. 5.3 ± 1.5, p = 0.03). Intradialytic systolic BP was higher during HD(ind) versus HD(37) (p < 0.001). Individualised body temperature dialysis demonstrated symptomatic tolerability comparable to HD(37).

Conclusions: Individualised-temperature haemodialysis abrogates stunning, providing effective haemodynamic stabilisation at no additional therapy cost.

Publication types

  • Clinical Trial
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Blood Pressure
  • Body Temperature
  • Cross-Over Studies
  • Dialysis Solutions
  • Echocardiography
  • Female
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / physiopathology
  • Hemodynamics*
  • Humans
  • Kidney Failure, Chronic / physiopathology
  • Kidney Failure, Chronic / therapy*
  • Male
  • Middle Aged
  • Myocardial Stunning / diagnostic imaging
  • Myocardial Stunning / etiology
  • Myocardial Stunning / physiopathology
  • Myocardial Stunning / prevention & control*
  • Precision Medicine / economics
  • Precision Medicine / methods*
  • Prospective Studies
  • Renal Dialysis / adverse effects*
  • Systole / physiology*
  • Temperature

Substances

  • Dialysis Solutions