Method for quantitative analysis of flocculation performance

Water Res. 2011 May;45(10):3075-84. doi: 10.1016/j.watres.2011.03.021. Epub 2011 Mar 21.

Abstract

The sedimentation rate and the post-sedimentation residual turbidity of flocculated suspensions are properties central to the design and operation of unit processes following flocculation in a water treatment plant. A method for comparing flocculation performance based on these two properties is described. The flocculation residual turbidity analyzer (FReTA) records the turbidity of flocculent suspensions undergoing quiescent settling. The fixed distance across which flocs must travel to clear the measurement volume allows sedimentation velocity distributions of the flocculent suspension to be calculated from the raw turbidity data. By fitting the transformed turbidity data with a modified gamma distribution, the mean and variance of sedimentation velocity can be obtained along with the residual turbidity after a period of settling. This new analysis method can be used to quantitatively compare how differences in flocculator operating conditions affect the sedimentation velocity distribution of flocs as well as the post-sedimentation residual turbidity.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Alum Compounds / chemistry
  • Flocculation
  • Nephelometry and Turbidimetry / instrumentation
  • Reproducibility of Results
  • Software
  • Water Purification / instrumentation
  • Water Purification / methods*

Substances

  • Alum Compounds