Introduction: Coronary revascularization (CR) may reduce arrhythmia risk and improve long-term outcome in patients with left ventricular dysfunction. This study was designed to evaluate the effect of elapsed time from CR on long-term mortality and arrhythmic risk among patients who receive an implantable cardioverter defibrillator (ICD).

Methods and results: We evaluated the risk of 8-year mortality by elapsed time from CR to ICD implantation (categorized as: no CR; recent CR [<2 years]; or nonrecent CR [≥2 years], and assessed as a continuous measure) among 720 ICD recipients enrolled in the Multicenter Automatic Defibrillator Trial-II. At 8 years of follow-up, patients who did not undergo CR and those who underwent nonrecent CR had significantly higher mortality rates than patients who underwent recent CR (54%, 54%, and 36%, respectively; P < 0.001). Multivariate analysis demonstrated that no- and nonrecent CR were associated with respective 48% (P = 0.022) and 67% (P < 0.001) increases in mortality risk compared with recent CR. Assessment of time from CR as a continuous measure showed that every year elapsed from CR was associated with an adjusted 6% increase in 8-year mortality (P < 0.001), and in respective 6% (P < 0.001) and 6% (P = 0.003) increased risk for in-trial appropriate ICD therapy of ventricular tachyarrhythmias and appropriate ICD shocks.

Conclusions: We observed a direct relationship between elapsed time from CR and long-term mortality following ICD implantation. The favorable long-term effect on outcome of recent CR may be related to a time-dependent effect of CR on ventricular arrhythmic burden and the need for appropriate ICD shocks.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Analysis of Variance
  • Arrhythmias, Cardiac / etiology
  • Arrhythmias, Cardiac / mortality
  • Arrhythmias, Cardiac / prevention & control*
  • Chi-Square Distribution
  • Death, Sudden, Cardiac / etiology
  • Death, Sudden, Cardiac / prevention & control*
  • Defibrillators, Implantable* / adverse effects
  • Electric Countershock / adverse effects
  • Electric Countershock / instrumentation*
  • Electric Countershock / mortality
  • Female
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Myocardial Infarction / complications
  • Myocardial Infarction / mortality
  • Myocardial Infarction / therapy*
  • Myocardial Revascularization* / adverse effects
  • Myocardial Revascularization* / mortality
  • Proportional Hazards Models
  • Risk Assessment
  • Risk Factors
  • Survival Rate
  • Time Factors
  • Treatment Outcome
  • Ventricular Dysfunction, Left / etiology
  • Ventricular Dysfunction, Left / mortality
  • Ventricular Dysfunction, Left / therapy*