Beyond the short-term: clinical outcome and valve performance 2 years after transcatheter aortic valve implantation in 227 patients

J Thorac Cardiovasc Surg. 2012 Feb;143(2):310-7. doi: 10.1016/j.jtcvs.2011.10.060. Epub 2011 Dec 3.

Abstract

Objective: Although the procedural feasibility of transcatheter aortic valve implantation has been shown by multiple groups, longer-term data are rare. We report on 2-year follow-up clinical and echocardiographic results after transcatheter aortic valve implantation in 227 patients.

Methods: Patients' mean age was 81 ± 7 years, 59% were female, mean European System for Cardiac Operative Risk Evaluation was 21% ± 14%, mean Society of Thoracic Surgeons score was 7% ± 5%, and access routes were transfemoral (n = 164), transapical (n = 54), axillary (n = 5), or transaortic (n = 4). A CoreValve (Medtronic Inc, Minneapolis, Minn) prosthesis was implanted in 174 patients, and a SAPIEN prosthesis (Edwards Lifesciences, Irvine, Calif) was implanted in 53 patients. Clinical and echocardiographic investigations were performed at 6 months, 1 year, and 2 years.

Results: Survival was 88.5% at 30 days, 75.9% at 6 months, 74.5% at 1 year, and 64.4% at 2 years. Patients improved significantly in New York Heart Association class after 6 months (from 3.2 ± 0.5 to 1.7 ± 0.7, P < .001) and up to 2 years (1.9 ± 0.7). Cumulative incidences of myocardial infarction, stroke, and life-threatening or major bleeding were 2.7%, 6.2%, and 16.2% at 2 years, respectively. The postprocedural mean transprosthetic gradient was 12 ± 4 mm Hg for all valves and did not change up to 2 years, and the effective orifice area was 1.5 ± 0.4 cm² with no change over 2 years of follow-up. Moderate or severe prosthetic regurgitation was present in 8% of patients at 2 years. In 6% of patients, the paravalvular or valvular regurgitation grade increased significantly over time.

Conclusions: With excellent functional recovery of the patients, good systolic valve function, and overall low morbidity at 2 years, transcatheter aortic valve implantation may be considered the treatment of choice for aortic valve stenosis in elderly patients with an increased risk for surgery with a heart-lung machine.

MeSH terms

  • Age Factors
  • Aged
  • Aged, 80 and over
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / therapy*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cardiac Catheterization / mortality
  • Female
  • Germany
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemorrhage / etiology
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Myocardial Infarction / etiology
  • Patient Selection
  • Prosthesis Design
  • Recovery of Function
  • Risk Assessment
  • Risk Factors
  • Severity of Illness Index
  • Stroke / etiology
  • Time Factors
  • Treatment Outcome
  • Ultrasonography