The sirolimus-eluting Cypher Select coronary stent for the treatment of bare-metal and drug-eluting stent restenosis: insights from the e-SELECT (Multicenter Post-Market Surveillance) registry

JACC Cardiovasc Interv. 2012 Jan;5(1):64-71. doi: 10.1016/j.jcin.2011.09.016.

Abstract

Objectives: This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients.

Background: There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR.

Methods: The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year.

Results: Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p < 0.001), renal insufficiency (5.8% vs. 2.3%, p = 0.003), and prior coronary artery bypass graft (20.5% vs. 11.8%, p < 0.001). At 1 year, death (1.4% for BMS vs. 2.1% for DES, p = 0.3) and myocardial infarction (2.4% for BMS and 3.3% for DES, p = 0.3) rates were similar, whereas ischemia-driven target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively).

Conclusions: Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern.

Publication types

  • Evaluation Study
  • Multicenter Study

MeSH terms

  • Angioplasty, Balloon, Coronary*
  • Coronary Restenosis / mortality
  • Coronary Restenosis / prevention & control*
  • Databases, Factual
  • Drug-Eluting Stents / adverse effects
  • Drug-Eluting Stents / statistics & numerical data*
  • Europe
  • Female
  • Health Status Indicators
  • Humans
  • Immunosuppressive Agents / therapeutic use*
  • Internationality
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Product Surveillance, Postmarketing
  • Registries
  • Sirolimus / therapeutic use*
  • Statistics as Topic

Substances

  • Immunosuppressive Agents
  • Sirolimus