Impact of MRI-based postimplant dosimetric assessment in prostate brachytherapy using contrast-enhanced T1-weighted images

Brachytherapy. 2012 Nov-Dec;11(6):468-75. doi: 10.1016/j.brachy.2011.12.010. Epub 2012 Feb 11.

Abstract

Purpose: To compare contrast-enhanced T1-weighted (CE-T1WI) magnetic resonance imaging (MRI) with computed tomography (CT) for postimplant dosimetry and seed recognition in prostate brachytherapy.

Methods and materials: A total of 245 patients who received (125)I prostate brachytherapy with or without external beam radiotherapy were enrolled. For postimplant analysis, CT and MRI scans were obtained at 1 month after seed implantation. For MRI-based dosimetry, T2-weighted images were fused with the CE-T1WI; the prostate was delineated on the T2-weighted images, and the seed detection was performed manually on the CE-T1WI. In CT-based dosimetry, the seed detection was essentially performed automatically. The dosimetric results obtained by MRI-based and CT-based dosimetry were compared.

Results: The mean prostate D(90) (the minimum dose received by 90% of the prostate volume) estimated by MRI-based and CT-based dosimetry were 113% and 115%, respectively, with no significant difference. The mean prostate V(100) (the percent volume of the postimplant prostate receiving 100% of the prescribed dose) estimated by MRI-based and CT-based dosimetry were 95.2% and 95.8%, respectively, again with no significant difference. The mean prostate V(150) (the percent volume of the postimplant prostate receiving 150% of the prescribed dose) estimated by MRI-based and CT-based dosimetry were 52.8% and 57.0%, respectively (p<0.01). In all of the 35 patients (14%) in whom the MRI-based V(150) were at least 10% lower than the CT-based results, the seed detection by CT-based dosimetry was overestimated in highly seed-clustered areas or in the areas close to calcifications because of reconstruction artifacts in CT images.

Conclusions: MRI-based dosimetry using CE-T1WI appears to be acceptable. Our results suggest that MRI-based dosimetry is a practical method for estimation of the higher dose distribution, especially if seeds are clustered together or when they are close to calcifications.

Publication types

  • Clinical Trial

MeSH terms

  • Aged
  • Aged, 80 and over
  • Brachytherapy / methods
  • Brachytherapy / statistics & numerical data*
  • Contrast Media
  • Gadolinium DTPA*
  • Humans
  • Image Enhancement / methods
  • Japan / epidemiology
  • Magnetic Resonance Imaging / methods
  • Magnetic Resonance Imaging / statistics & numerical data*
  • Male
  • Middle Aged
  • Prevalence
  • Prostatic Neoplasms / epidemiology
  • Prostatic Neoplasms / pathology*
  • Prostatic Neoplasms / radiotherapy*
  • Radiometry / methods*
  • Radiotherapy Dosage
  • Radiotherapy, Image-Guided / methods
  • Radiotherapy, Image-Guided / statistics & numerical data*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Treatment Outcome