Objectives: This study evaluated the use of a paclitaxel-eluting balloon (PEB) for treatment of femoropopliteal arterial disease.
Background: Conventional balloon angioplasty and stenting in this setting is associated with high restenosis rates within 12 months. Recent data suggest that PEB use may reduce restenosis. Twelve-month outcomes following PEB use with provisional stenting are described.
Methods: This prospective registry enrolled patients (Rutherford class 2 to 4) with reference vessel diameter of 3 to 7 mm and lesion/occlusion length ≤ 15 cm. Endpoints included primary patency rate, target lesion revascularization, and changes in Rutherford class and ankle-brachial index. Walking capacity, absolute claudication distance, and quality of life were also assessed.
Results: The registry enrolled 105 patients. Baseline ankle-brachial index was 0.56 ± 0.15. Baseline Rutherford classification was class 2 or 3 for most patients (91.5%). Most lesions were located in the superficial femoral artery (77.1%). Mean lesion length was 76.3 ± 38.3 mm; 29.8% of lesions were total occlusions. The device was successfully used in all patients and only 12.3% of lesions required stenting. At 12-month follow-up, 92 of 105 patients (87.6%) were evaluable; the primary patency rate was 83.7%; the target lesion revascularization rate was 7.6%; 85.6% of patients were Rutherford class 0 or 1; and mean ankle-brachial index was 0.86 ± 0.15. Quality of life and absolute claudication distance showed significant improvement from baseline to 12-month follow-up.
Conclusions: PEB treatment of femoropopliteal arterial disease resulted in consistent clinical improvement across multiple endpoints with a low rate of stenting and target lesion revascularization.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.