Abstract
An 8-month-old female with hypoplastic left heart syndrome had undergone bidirectional cavopulmonary anastomosis at the age of 4.5 months and presented with a new continuous flow murmur on routine follow-up. Diagnostic catheterization demonstrated a fistula between the left atrial appendage and the neo-aortic arch. The fistula was sealed with an Amplatzer Vascular Occluder II device without complications.
Copyright © 2012 Wiley Periodicals, Inc.
MeSH terms
-
Aorta, Thoracic / diagnostic imaging
-
Aorta, Thoracic / surgery*
-
Aortic Diseases / diagnosis
-
Aortic Diseases / etiology
-
Aortic Diseases / therapy*
-
Aortography
-
Atrial Appendage*
-
Cardiac Catheterization / instrumentation*
-
Equipment Design
-
Female
-
Fistula / diagnosis
-
Fistula / etiology
-
Fistula / therapy*
-
Fontan Procedure / adverse effects*
-
Heart Diseases / diagnosis
-
Heart Diseases / etiology
-
Heart Diseases / therapy*
-
Humans
-
Hypoplastic Left Heart Syndrome / surgery*
-
Infant
-
Radiography, Interventional
-
Treatment Outcome