Magnetic resonance evaluation of renal artery stenosis in a swine model: performance of low-dose gadobutrol versus gadoterate meglumine in comparison with digital subtraction intra-arterial catheter angiography

Invest Radiol. 2012 Jun;47(6):376-82. doi: 10.1097/RLI.0b013e3182539554.

Abstract

Purpose: The aim of this study was to compare low-dose imaging with gadobutrol and gadoterate meglumine (Gd-DOTA) for evaluation of renal artery stenosis with 3-T magnetic resonance angiography (MRA) in a swine model.

Method and materials: A total of 12 experimental animals were evaluated using equivalently dosed gadobutrol and Gd-DOTA for time-resolved and static imaging. For time-resolved imaging, the time-resolved imaging with stochastic trajectories (TWIST) technique (temporal footprint, 4.4 seconds) was used; a dose of 1 mL of gadobutrol was injected at 2 mL/s and a dose of 2 mL of Gd-DOTA was injected at both 2 and 4 mL/s. For a separate static acquisition, doses were doubled. The static scans were used for stenosis gradation and the time-resolved scans for comparison of enhancement dynamics, signal-to-noise ratio (SNR), and qualitative assessments.

Results: The average magnitude of difference in the stenosis measurements with static gadobutrol scans relative to digital subtraction intra-arterial catheter angiography (mean [SD], 7.4% [5.6%]) was less than with both the 2 mL/s (10.6% [6.2%]) and 4 mL/s (11.5% [7.8%]) Gd-DOTA MRA protocols. On time-resolved scans, peak signal-to-noise ratio was greatest with the gadobutrol protocol (P < 0.05), and the gadobutrol TWIST scan was preferred to the TWIST Gd-DOTA scan in terms of image quality and stenosis visualization in every case for every reader.

Conclusion: Low-dose gadobutrol (~0.05 mmoL/kg) contrast-enhanced MRA results in improved accuracy of renal artery stenosis assessments relative to equivalently dosed Gd-DOTA at 3 T.

Publication types

  • Comparative Study

MeSH terms

  • Angiography, Digital Subtraction / methods*
  • Animals
  • Catheterization, Peripheral / methods
  • Contrast Media / administration & dosage
  • Disease Models, Animal*
  • Dose-Response Relationship, Drug
  • Female
  • Humans
  • Magnetic Resonance Angiography / methods*
  • Male
  • Meglumine* / administration & dosage
  • Organometallic Compounds* / administration & dosage
  • Renal Artery Obstruction / pathology*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Swine

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadobutrol
  • Meglumine
  • gadoterate meglumine