Applicability of a risk score for prediction of the long-term (8-year) benefit of the implantable cardioverter-defibrillator

J Am Coll Cardiol. 2012 Jun 5;59(23):2075-9. doi: 10.1016/j.jacc.2012.02.036.

Abstract

Objectives: The present study was designed to explore the 8-year survival benefit of a nonresynchronization implantable cardioverter-defibrillator (ICD) according to a simple risk stratification score.

Background: There is limited information regarding factors that predict the benefit of primary prevention with an ICD during long-term follow-up.

Methods: This study used a previously developed risk score including 5 clinical factors (New York Heart Association functional class >II, age >70 years, blood urea nitrogen >26 mg/dl, QRS duration >0.12 s, and atrial fibrillation) to evaluate 8-year ICD survival benefit within risk score categories among 1,191 MADIT-II (Multicenter Automatic Defibrillator Implantation Trial II) patients.

Results: Patients with low (0 risk factors, n = 345) and intermediate risk (1 to 2 risk factors, n = 646) demonstrated a significantly higher probability of survival at 8-year follow-up when treated by ICD as compared with non-ICD therapy (75% vs. 58%, p = 0.004; and 47% vs. 31%, p < 0.001, respectively). By contrast, among high-risk patients (3 or more risk factors, n = 200), there was no significant difference in 8-year survival between the ICD and non-ICD subgroups (19% vs. 17%, p = 0.50). Consistently, multivariate analysis showed that ICD therapy was associated with a significant long-term survival benefit among low- and intermediate-risk patients (hazard ratio [HR]: 0.52, p < 0.001, and HR: 0.66, p < 0.001, respectively), whereas treatment with an ICD was not associated with a significant benefit among high-risk patients (HR: 0.84, p = 0.25).

Conclusions: These findings suggest that a simple risk score can identify patients who derive significant long-term benefit from primary ICD therapy. High-risk patients with multiple comorbidities composed 17% of the MADIT-II population and did not derive long-term benefit from nonresynchronization device therapy.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Age Factors
  • Aged
  • Cause of Death*
  • Confidence Intervals
  • Defibrillators, Implantable / adverse effects*
  • Female
  • Follow-Up Studies
  • Heart Failure / etiology
  • Heart Failure / mortality
  • Heart Failure / therapy*
  • Heart Function Tests
  • Hospital Mortality / trends
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Myocardial Infarction / complications*
  • Myocardial Infarction / diagnosis
  • Myocardial Infarction / mortality
  • Proportional Hazards Models
  • Risk Assessment
  • Severity of Illness Index
  • Sex Factors
  • Stroke Volume*
  • Survival Analysis
  • Time Factors