Determination of NVP-BEZ235, a dual PI3K and mTOR inhibitor, in human and mouse plasma and in mouse tissue homogenates by reversed-phase high-performance liquid chromatography with fluorescence detection

J Chromatogr B Analyt Technol Biomed Life Sci. 2012 Jul 15:901:9-17. doi: 10.1016/j.jchromb.2012.05.033. Epub 2012 Jun 8.

Abstract

NVP-BEZ235 is a novel dual inhibitor of PI3K/mTOR and currently undergoing phase I/II clinical trials for advanced solid tumors. We developed a sensitive and selective reversed-phase high-performance liquid chromatographic (HPLC) assay with fluorometric detection for quantification of NVP-BEZ235 in biological matrices. Liquid-liquid extraction with tert-butyl methyl ether was used for sample pre-treatment, yielding a recovery of >84%. Chromatographic separation of NVP-BEZ235 and the internal standard (IS) NVP-BBD130 was achieved on a GraceSmart C-18 column by isocratic elution with a mobile phase which consisted of acetonitrile, methanol, and milliQ water adjusted with acetic acid to pH 3.7 (20:36:44, v/v/v). Fluorescence detection using excitation and emission wavelengths of 270 and 425 nm, respectively, provided a selectivity and sensitivity allowing quantification down to 1 ng/ml in human plasma and linear calibration curves within a range of 1-1000 ng/ml. The assay was validated for human plasma, mouse plasma and a range of tissues. The accuracy, within-day and between-day precision for all matrices, was within the generally accepted 15% range. NVP-BEZ235 was stable for 72 h in pretreated samples in reconstitution mixture (acetonitrile-water (30:70, v/v)), but unstable in mouse tissue homogenates upon repeated freeze-thaw cycles or long term storage (≥24 h) at room temperature. A pilot pharmacokinetic study in mice demonstrated the applicability of this method for pharmacokinetic purposes. Overall, this assay is suitable for the pharmacokinetic studies of NVP-BEZ235 in mice and in human plasma.

MeSH terms

  • Animals
  • Chromatography, High Pressure Liquid / methods*
  • Chromatography, Reverse-Phase / methods*
  • Drug Stability
  • Humans
  • Imidazoles / analysis*
  • Imidazoles / blood
  • Imidazoles / pharmacokinetics
  • Linear Models
  • Liquid-Liquid Extraction
  • Mice
  • Quinolines / analysis*
  • Quinolines / blood
  • Quinolines / pharmacokinetics
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Spectrometry, Fluorescence
  • Tissue Distribution

Substances

  • Imidazoles
  • Quinolines
  • dactolisib