Long-term results of carbon ion radiation therapy for locally advanced or unfavorably located choroidal melanoma: usefulness of CT-based 2-port orthogonal therapy for reducing the incidence of neovascular glaucoma

Int J Radiat Oncol Biol Phys. 2013 Jun 1;86(2):270-6. doi: 10.1016/j.ijrobp.2012.12.022. Epub 2013 Feb 13.

Abstract

Purpose: To determine the long-term results of carbon ion radiation therapy (C-ion RT) in patients with choroidal melanoma, and to assess the usefulness of CT-based 2-port irradiation in reducing the risk of neovascular glaucoma (NVG).

Methods and materials: Between January 2001 and February 2012, a total of 116 patients with locally advanced or unfavorably located choroidal melanoma received CT-based C-ion RT. Of these patients, 114 were followed up for more than 6 months and their data analyzed. The numbers of T3 and T2 patients (International Union Against Cancer [UICC], 5th edition) were 106 and 8, respectively. The total dose of C-ion RT varied from 60 to 85 GyE, with each dose given in 5 fractions. Since October 2005, 2-port therapy (51 patients) has been used in an attempt to reduce the risk of NVG. A dose-volume histogram analysis was also performed in 106 patients.

Results: The median follow-up was 4.6 years (range, 0.5-10.6 years). The 5-year overall survival, cause-specific survival, local control, distant metastasis-free survival, and eye retention rates were 80.4% (95% confidence interval 89.0%-71.8%), 82.2% (90.6%-73.8%), 92.8% (98.5%-87.1%), 72.1% (81.9%-62.3%), and 92.8% (98.1%-87.5%), respectively. The overall 5-year NVG incidence rate was 35.9% (25.9%-45.9%) and that of 1-port group and 2-port group were 41.6% (29.3%-54.0%) and 13.9% (3.2%-24.6%) with statistically significant difference (P<.001). The dose-volume histogram analysis showed that the average irradiated volume of the iris-ciliary body was significantly lower in the non-NVG group than in the NVG group at all dose levels, and significantly lower in the 2-port group than in the 1-port group at high dose levels.

Conclusions: The long-term results of C-ion RT for choroidal melanoma are satisfactory. CT-based 2-port C-ion RT can be used to reduce the high-dose irradiated volume of the iris-ciliary body and the resulting risk of NVG.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Choroid Neoplasms / diagnostic imaging
  • Choroid Neoplasms / mortality
  • Choroid Neoplasms / pathology
  • Choroid Neoplasms / radiotherapy*
  • Ciliary Body / radiation effects
  • Female
  • Glaucoma, Neovascular / epidemiology
  • Glaucoma, Neovascular / etiology
  • Glaucoma, Neovascular / prevention & control*
  • Heavy Ion Radiotherapy / adverse effects
  • Heavy Ion Radiotherapy / methods*
  • Humans
  • Incidence
  • Iris / radiation effects
  • Male
  • Melanoma / diagnostic imaging
  • Melanoma / mortality
  • Melanoma / pathology
  • Melanoma / radiotherapy*
  • Middle Aged
  • Neoplasm Recurrence, Local / pathology
  • Radiotherapy Dosage
  • Tomography, X-Ray Computed / methods
  • Treatment Outcome
  • Young Adult