Aims: This study aimed to identify whether left atrial (LA) volume assessed by multidetector computed tomography (MDCT) is related to the long-term success of pulmonary vein ablation (PVA). MDCT is used to guide PVA for the treatment of atrial fibrillation (AF). MDCT permits accurate sizing of LA dimensions.
Methods and results: We analysed data from 368 ablation procedures of 279 consecutive patients referred for PVA due to drug-refractory symptomatic AF (age 62 ± 10; 58% men; 71% paroxysmal AF). Prior to the procedure, all patients underwent ECG-gated 64-MDCT scan for assessment of LA and PV anatomy, LA thrombus evaluation, LA volume estimation, and electroanatomical mapping integration. Within a mean follow-up of 356 ± 128 days, 64% of the patients maintained sinus rhythm after the initial ablation, and 84% when including repeat PVA. LA diameter (P = 0.004), LA volume (P = 0.002), and type of AF (P = 0.001) were independent predictors of AF recurrence in univariate analysis. There was a relatively low correlation between the echocardiographic LA diameter and LA volume from MDCT (P = 0.01, r = 0.5). In multivariate analysis, paroxysmal AF (P < 0.006) and LA volume below the median value of 106 mL (P = 0.042) were significantly associated with the success of PVA, whereas LA diameter was not (P = 0.245). Analysing receiver-operator characteristics, the area under the curve for LA volume was 0.73 (P = 0.001) compared with 0.60 (P = 0.09) for LA diameter from echocardiography.
Conclusion: LA volume assessed by MDCT is a better predictor of AF recurrence after PVA than echocardiograpic LA diameter and can be derived from the pre-procedural imaging data set.
Keywords: Atrial fibrillation; Left atrium; Multidetector computed tomography; Pulmonary vein ablation.