ProFit revisited

Magn Reson Med. 2014 Feb;71(2):458-68. doi: 10.1002/mrm.24703.

Abstract

Purpose: An enhanced version of the ProFit fitting tool was developed and validated to improve the quantification of two-dimensional JRPESS spectroscopic data.

Methods: The proposed enhancements were achieved by flexible organization of prior knowledge, configurations for different situations, the inclusion of measured macromolecular baseline contribution, additional baseline splines and a model-free lineshape based on self-deconvolution. The new software was tested and tuned on simulated data and subsequently applied to in vivo intrasubject and intersubject data.

Results: Fit results of simulated and acquired spectra show good overall quality suggesting the potential reliable detection of up to 18 metabolites on a 3T system yielding Cramer-Lower-Bounds below 20%.

Conclusion: The proposed enhanced version of ProFit together with two-dimensional J-resolved spectroscopy offers the opportunity to reliably detect a wide selection of important brain metabolites on 3T.

MeSH terms

  • Brain Chemistry
  • Humans
  • Magnetic Resonance Spectroscopy / methods*
  • Models, Theoretical
  • Software
  • Software Validation