Bridge to transplant with extracorporeal membrane oxygenation followed by HeartWare ventricular assist device in a child

Ann Thorac Surg. 2013 May;95(5):1780-2. doi: 10.1016/j.athoracsur.2012.09.088.

Abstract

A 10-year-old boy was admitted with dilated cardiomyopathy. Before scheduled implantation of a HeartWare ventricular assist device, he experienced a cardiac arrest and required extracorporeal membrane oxygenation for both cardiac and pulmonary support. After 4 days of extracorporeal membrane oxygenation and 126 days of support on the HeartWare ventricular assist device, he underwent successful cardiac transplantation. He is doing well 6 months after transplantation.

Publication types

  • Case Reports

MeSH terms

  • Child
  • Extracorporeal Membrane Oxygenation*
  • Heart Transplantation*
  • Heart-Assist Devices*
  • Humans
  • Male