A novel derivatization-based liquid chromatography tandem mass spectrometry method for quantitative characterization of naphthenic acid isomer profiles in environmental waters

J Chromatogr A. 2013 Jun 7:1293:36-43. doi: 10.1016/j.chroma.2013.03.040. Epub 2013 Mar 25.

Abstract

A method for quantitative characterization of naphthenic acid (NA) isomer groups by carbon number and extent of cyclization was developed and validated with water samples from northern Alberta. Following solid phase extraction, NAs undergo derivatization with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) allowing detection by positive electrospray ionization tandem mass spectrometry (+ESI)-MS/MS. NA-EDC derivatives produce a common product ion by MS/MS, regardless of structure of the starting NA. Thus, approximately constant relative response factors (RRFs) were assumed for the various isomer groups that elute at a given point in the elution gradient (supported by calculated RRFs for individual model NAs), facilitating quantification using a single standard (1-pyrenebutyric acid). To reduce the impact of major background fatty acids on NA data, the method employed an optimized liquid chromatography method that separated straight chain (Z=0) analytes from other NAs. Method validation was performed at two spiking levels (7.72μg and 38.6μg total refined Merichem per 500mL of reagent water) and good accuracy (mean recoveries of 82.4±2.5% and 93.0±2.6%, respectively; range ~50-130%) and precision (<17% RSD) were achieved at both spiking levels for all 60 NA isomer groups. The method also performed well in an independent method comparison study in which method accuracy values of 107%, 120%, and 121% were obtained for 2 spiked reagent waters (1mg/L and 50mg/L NAs) and spiked Athabasca River water (0.035mg/L NAs), respectively. Application of the method to samples from northern Alberta revealed that NA concentrations decreased in the order: process water (52.8mg/L)>tailings pond water (30.6mg/L)>well water (0.086mg/L)>surface water (0.007mg/L), and that samples were distinguishable by NA isomer profile using Principal components analysis.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Carboxylic Acids / analysis*
  • Carboxylic Acids / chemistry
  • Carboxylic Acids / isolation & purification
  • Chromatography, Liquid / methods*
  • Isomerism
  • Oil and Gas Fields / chemistry
  • Ponds / chemistry
  • Principal Component Analysis
  • Reproducibility of Results
  • Rivers / chemistry
  • Solid Phase Extraction
  • Spectrometry, Mass, Electrospray Ionization / methods
  • Tandem Mass Spectrometry / methods*
  • Water Pollutants, Chemical / analysis*
  • Water Pollutants, Chemical / chemistry

Substances

  • Carboxylic Acids
  • Water Pollutants, Chemical
  • naphthenic acid