Transjugular tricuspid valve-in-valve implantation

Heart Lung Circ. 2013 Dec;22(12):1036-9. doi: 10.1016/j.hlc.2013.04.113. Epub 2013 May 30.

Abstract

A 60 year-old female underwent tricuspid valve replacement in 2002. Post-operative recovery was complicated by severe post-pericardiotomy-syndrome. Seven years later she underwent transcatheter valve-in-valve implantation through the right jugular vein because of early prosthesis deterioration. Moreover intra-operative transoesophageal echocardiography showed an important right-to-left shunt through the patent foramen ovale that immediately disappeared after the deployment of a 29-mm Sapien-XT. The patient had an immediate and dramatic improvement in day-by-day activities. This case shows that tricuspid valve deterioration can be safely and successfully treated through this approach.

Keywords: Patent foramen ovale; TAVI; Transcatheter; Transjugular; Valve-in-valve.

Publication types

  • Case Reports

MeSH terms

  • Echocardiography, Transesophageal*
  • Female
  • Heart Valve Prosthesis Implantation*
  • Humans
  • Jugular Veins*
  • Middle Aged
  • Tricuspid Valve Insufficiency* / diagnostic imaging
  • Tricuspid Valve Insufficiency* / surgery
  • Tricuspid Valve* / diagnostic imaging
  • Tricuspid Valve* / surgery