Evaluation of blind nasotracheal suctioning and non-bronchoscopic mini-bronchoalveolar lavage in critically ill patients with infectious pneumonia: a preliminary study

Respir Care. 2014 Mar;59(3):345-52. doi: 10.4187/respcare.02356. Epub 2013 Jul 23.

Abstract

Background: We evaluated the diagnostic performance and safety of combined blind nasotracheal suctioning and non-bronchoscopic mini-bronchoalveolar lavage (mini-BAL) to obtain respiratory secretion specimens from spontaneously breathing, non-intubated patients with infectious pneumonia in intensive care.

Methods: Patients suspected of having infectious pneumonia were included prospectively. Three samples were obtained: expectorated sputum, nasotracheal suctioning, and mini-BAL via a double telescopic catheter (Combicath). Under local anesthesia, nasotracheal suctioning was done according to standard recommendations. Then mini-BAL was performed; the bronchial catheter serves as a guide for the mini-BAL catheter, and tracheal position is verified via colorimetric capnography.

Results: We included 36 subjects (29 men, median age 69 y, median Simplified Acute Physiology Score II 32), of which 32 (89%) underwent nasotracheal suctioning and mini-BAL, and from 13 (36%) we collected expectorated sputum. Based on colorimetric capnography confirmation of the tracheal position, 75% (24/32) of the successful combined procedures were achieved on the first attempt. The median duration of the combined procedure was 7 min. Bacterial pneumonia was diagnosed in 24/36 (67%) subjects, among whom 21 (88%) had undergone successful nasotracheal suctioning and mini-BAL, respectively, for 8/21 (38% [95% CI 0.17-0.58%] and 14/21 (67% [95% CI 0.46-0.86%]). Mini-BAL diagnosed a significantly higher percentage of bacterial pneumonias than did nasotracheal suctioning. Expectorated sputum yielded no diagnoses.

Conclusions: Blind nasotracheal suctioning confirmed via colorimetric capnography allows microbiological diagnosis, and can be enhanced by non-bronchoscopic mini-BAL. Colorimetric capnography helps confirm bronchial tube position. Non-bronchoscopic mini-BAL is a novel and feasible way to collect bronchial secretions without fibroscopy. (ClinicalTrials.gov NCT00763620.).

Keywords: blind nasotracheal suctioning; colorimetric capnography; expectorated sputum; intensive care; mini-bronchoalveolar lavage; pneumonia.

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Bronchoalveolar Lavage / instrumentation
  • Bronchoalveolar Lavage / methods*
  • Bronchoalveolar Lavage Fluid / microbiology*
  • Female
  • Humans
  • Intensive Care Units
  • Male
  • Middle Aged
  • Pneumonia, Bacterial / diagnosis*
  • Pneumonia, Bacterial / microbiology
  • Prospective Studies
  • Suction / instrumentation
  • Suction / methods

Associated data

  • ClinicalTrials.gov/NCT00763620