Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter

Heart Rhythm. 2013 Nov;10(11):1598-604. doi: 10.1016/j.hrthm.2013.07.044. Epub 2013 Jul 30.

Abstract

Background: In patients with atrial flutter who undergo cavotricuspid isthmus ablation, long-term electrocardiographic (ECG) monitoring may identify new onset of atrial fibrillation (AF).

Objectives: To ascertain, through the use of an implantable loop recorder (ILR) with a dedicated AF detection algorithm, the incidence, duration, and burden of new AF in these patients and to develop an optimal postablation ECG monitoring strategy.

Methods: We enrolled 20 patients with flutter, a CHADS2 score of 2-3, and no prior episode of AF. After cavotricuspid isthmus ablation, we implanted an ILR, which was interrogated routinely; all stored ECGs were adjudicated.

Results: During a mean follow-up of 382 ± 218 days, 3 patterns were observed. First, in 11 (55%) patients, stored ECGs confirmed AF at 62 ± 38 days after ablation. Second, in 4 (20%) patients, although the ILR suggested AF, episodes actually represented sinus rhythm with frequent premature atrial contractions and/or oversensing. Third, in 5 (25%) patients, no AF was observed. Episodes <4 hours were associated with low AF burden (<1%) or false detections. The 1-year freedom from any episode of AF >4 and >12 hours was 52% and 83%, respectively.

Conclusions: Our data show that many (but not all) patients develop new AF within the first 4 months of flutter ablation. Since external ECG monitoring for this duration is impractical, the ILR has an important role for long-term AF surveillance. Future research should be directed toward identifying the relationship between duration/burden of AF and stroke and improving existing ILR technology.

Keywords: AF; Atrial fibrillation; Atrial flutter; CTI; Catheter ablation; Cavotricuspid isthmus; ECG; ILR; Implantable loop recorder; PPV; atrial fibrillation; cavotricuspid isthmus; electrocardiographic; implantable loop recorder; positive predictive value.

MeSH terms

  • Aged
  • Atrial Fibrillation / diagnosis*
  • Atrial Fibrillation / etiology
  • Atrial Fibrillation / physiopathology
  • Atrial Flutter / physiopathology
  • Atrial Flutter / surgery*
  • Catheter Ablation / adverse effects*
  • Electrocardiography, Ambulatory / instrumentation*
  • Electrodes, Implanted*
  • Female
  • Follow-Up Studies
  • Heart Conduction System / physiopathology
  • Heart Conduction System / surgery*
  • Humans
  • Male
  • Postoperative Complications
  • Prognosis
  • Time Factors
  • Tricuspid Valve / physiopathology
  • Vena Cava, Inferior / physiopathology