[Nearby perforator flaps as alternative choices for anterolateral thigh flap when lacking useful perforator]

Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2013 Jun;48(6):486-9.
[Article in Chinese]

Abstract

Objective: To explore the proposal using nearby perforator flaps as alternative reconstructive choices for anterolateral thigh (ALT) flap when lacking useful perforator.

Methods: From August 2010 to August 2012, 8 cases with head and neck cancer were found lacking reliable perforator during ALT flap elevation, a tensor fascia latae (TFL) flap or an anteromedial thigh (AMT) flap was used to complete the reconstruction.

Results: All 8 alternative flaps were successfully harvested, other donor sites were not needed. Flap harvest time was 50-85 min. Of 5 TFL flaps, pedicle lengths were 6-10 cm, and the diameters of the arteries and veins were 2.5-3.0 mm and 2.5-3.5 mm respectively. Of 3 AMT flaps, pedicle lengths were 10-15 cm, the rectus femoris branch was used as pedicle in 1 flap, with artery and vein more than 1.0 mm in diameter, and the descending branch of the lateral circumflex femoral artery was used as pedicle in other 2 flaps, the diameters of the arteries were 3.5 and 3.0 mm respectively, the diameters of the veins were 3.5 mm. The donor sites were directly closed in 7 cases and skin graft was performed in another case. All the flaps were alive and no complication was found in the donor sites.

Conclusion: TFL or AMT flap is an good alternative to ALT flap lacking useful perforator.