Objective: The objective of this study was to analyze differences in biomarker outcomes before and after harmonization of cerebrospinal fluid (CSF) collection tubes in Alzheimer's disease (AD) diagnosis.
Methods: We analyzed data from French memory centers that switched from different CSF collection tubes to a common one. A total of 1966 patients were included in the study. CSF concentrations of β-amyloid 1-42 (Aβ42), total tau, and phosphorylated tau (p-tau181) were measured in each center using the same commercial enzyme-linked immunoabsorbent assay (ELISA) kits. The diagnostic value of CSF biomarkers according to the type of tube used was then assessed using different cutoffs.
Results: The predictive value of Aβ42 was highly affected by the type of collection tube used. The optimal cutoff value for p-tau181 appeared not to be affected by the type of collection tube whereas that of total tau was slightly changed. New optimal cutoff values were then computed.
Conclusions: In a routine clinical environment, the selection of the collection tube and biomarker cutoff value makes a major difference in AD biological diagnosis. The use of a common collection tube among different centers will reduce the risk of misdiagnosis and incorrect patient stratification.
Keywords: Alzheimer's disease; Biomarkers; Cerebrospinal fluid; Diagnosis; Preanalytics.