Towards a consensus on a hearing preservation classification system

Acta Otolaryngol Suppl. 2013:(564):3-13. doi: 10.3109/00016489.2013.869059.

Abstract

Conclusion: The comprehensive Hearing Preservation classification system presented in this paper is suitable for use for all cochlear implant users with measurable pre-operative residual hearing. If adopted as a universal reporting standard, as it was designed to be, it should prove highly beneficial by enabling future studies to quickly and easily compare the results of previous studies and meta-analyze their data.

Objectives: To develop a comprehensive Hearing Preservation classification system suitable for use for all cochlear implant users with measurable pre-operative residual hearing.

Methods: The HEARRING group discussed and reviewed a number of different propositions of a HP classification systems and reviewed critical appraisals to develop a qualitative system in accordance with the prerequisites.

Results: The Hearing Preservation Classification System proposed herein fulfills the following necessary criteria: 1) classification is independent from users' initial hearing, 2) it is appropriate for all cochlear implant users with measurable pre-operative residual hearing, 3) it covers the whole range of pure tone average from 0 to 120 dB; 4) it is easy to use and easy to understand.

MeSH terms

  • Audiometry, Pure-Tone*
  • Auditory Threshold*
  • Cochlear Implantation
  • Cochlear Implants
  • Consensus
  • Humans