Right ventricular outflow tract enlargement prior to pulmonary valve replacement is associated with poorer structural and functional outcomes, in adults with repaired Tetralogy of Fallot

Heart Lung Circ. 2014 May;23(5):482-8. doi: 10.1016/j.hlc.2013.11.009. Epub 2013 Nov 28.

Abstract

Background: Pulmonary valve replacement (PVR) is commonly performed late after Tetralogy of Fallot (TOF) repair. We examined the effects of PVR on cardiac structure, function and exercise capacity in adults with repaired TOF.

Methods: Eighteen adult patients with repaired TOF and severe pulmonary regurgitation (PR) with right ventricular (RV) dilatation requiring PVR for clinical reasons (age; 25±8 years) were recruited to undergo cardiac MRI (1.5T) and cardiopulmonary exercise testing before and 14±3 months after PVR.

Results: Reduced indexed RV end-diastolic volume (RVEDVi; 186±32mL/m(2) pre-op vs 114±20mL/m(2) post-op, p<0.001) was observed after PVR. "Normalisation" of RVEDVi (≤108mL/m(2)) was achieved in only seven of 18 patients. Pre-PVR RVEDVi correlated with post-operative change in RVEDVi (change=-72.1±20.4mL/m(2), r=-0.815, p<0.001). Exercise capacity remained high-normal post-PVR (% predicted maximal workload: 93±16% vs 91±12%, p=0.5). Regional RV volumes were assessed; RV outflow tract (RVOT) volumes were compared to the RV muscular corpus. Large pre-PVR RVOT volumes correlated negatively with post-surgical RV ejection fraction, peak VO2 and delta VO2 at anaerobic threshold (p<0.05 for all).

Conclusions: Normalisation of RV volume is unlikely to be achieved above a pre-PVR RVEDVi of 165mL/m(2) or more. In particular, an enlarged RVOT prior to PVR predicts suboptimal structural and functional outcomes.

Keywords: Adult congenital heart disease; Cardiac magnetic resonance imaging; Cardiopulmonary exercise test; Pulmonary valve replacement; Right ventricular dilatation; Tetralogy of Fallot.

Publication types

  • Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Female
  • Heart Valve Prosthesis Implantation*
  • Humans
  • Magnetic Resonance Imaging
  • Male
  • Pulmonary Valve Insufficiency* / diagnostic imaging
  • Pulmonary Valve Insufficiency* / physiopathology
  • Pulmonary Valve Insufficiency* / surgery
  • Pulmonary Valve* / diagnostic imaging
  • Pulmonary Valve* / physiopathology
  • Pulmonary Valve* / surgery
  • Radiography
  • Tetralogy of Fallot* / diagnostic imaging
  • Tetralogy of Fallot* / physiopathology
  • Tetralogy of Fallot* / surgery
  • Ventricular Dysfunction, Right* / diagnostic imaging
  • Ventricular Dysfunction, Right* / physiopathology
  • Ventricular Dysfunction, Right* / surgery