Impact of rapid on-site evaluation on the adequacy of endoscopic-ultrasound guided fine-needle aspiration of solid pancreatic lesions: a systematic review and meta-analysis

J Gastroenterol Hepatol. 2014 Apr;29(4):697-705. doi: 10.1111/jgh.12431.

Abstract

Background: Rapid on-site evaluation (ROSE) has the potential to improve adequacy rates for endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic lesions, but its impact is context-dependent. No studies exist that summarize the relationship between ROSE, number of needle passes, and resulting adequacy rates.

Aims: To analyze data from previous studies to establish if ROSE is associated with improved adequacy rates; to evaluate the relationship between ROSE, number of needle passes, and the resulting adequacy rates of EUS-FNA for solid pancreatic lesions.

Methods: Systematic review and meta-analysis of studies reporting the adequacy rates for EUS-FNA of solid pancreatic lesions.

Results: The search produced 3822 original studies, of which 70 studies met our inclusion criteria. The overall average adequacy rate was 96.2% (95% confidence interval: 95.5, 96.9). ROSE was associated with a statistically significant improvement of up to 3.5% in adequacy rates. There was heterogeneity in adequacy rates across all subgroups. No association between the assessor type and adequacy rates was found. Studies with ROSE have high per-case adequacy and a relatively high number of needle passes in contrast to non-ROSE studies. ROSE is an effect modifier of the relationship between number of needle passes and adequacy.

Conclusions: ROSE is associated with up to 3.5% improvement in adequacy rates for EUS-FNA of solid pancreatic lesions. ROSE assessor type has no impact on adequacy rates. ROSE is an effect modifier on the relationship between needle passes and per-case adequacy for EUS-FNA of solid pancreatic lesions.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Databases, Bibliographic*
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration / methods*
  • Endoscopic Ultrasound-Guided Fine Needle Aspiration / statistics & numerical data*
  • Humans
  • Pancreatic Diseases / diagnosis*
  • Pancreatic Diseases / pathology*
  • Sensitivity and Specificity