An ion-exchange nanomembrane sensor for detection of nucleic acids using a surface charge inversion phenomenon

Biosens Bioelectron. 2014 Oct 15:60:92-100. doi: 10.1016/j.bios.2014.04.008. Epub 2014 Apr 13.

Abstract

We present a novel low-cost biosensor for rapid, sensitive and selective detection of nucleic acids based on an ionic diode feature of an anion exchange nanoporous membrane under DC bias. The ionic diode feature is associated with external surface charge inversion on the positively charged anion exchange nanomembrane upon hybridization of negatively charged nucleic acid molecules to single-stranded oligoprobes functionalized on the membrane surface resulting in the formation of a cation selective monolayer. The resulting bipolar membrane causes a transition from electroconvection-controlled to water-splitting controlled ion conductance, with a large ion current signature that can be used to accurately quantify the hybridized nucleic acids. The platform is capable of distinguishing two base-pair mismatches in a 22-base pairing segment of microRNAs associated with oral cancer, as well as serotype-specific detection of dengue virus. We also show the sensor' capability to selectively capture target nucleic acids from a heterogeneous mixture. The limit of detection is 1 pM for short 27 base target molecules in a 15-min assay. Similar hybridization results are shown for short DNA molecules as well as RNAs from Brucella and Escherichia coli. The versatility and simplicity of this low-cost biosensor should enable point-of-care diagnostics in food, medical and environmental safety markets.

Keywords: Biosensing; Charge inversion; DNA/RNA; Electrokinetics; Nanoporous membrane.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Base Sequence
  • Biosensing Techniques / instrumentation
  • Chromatography, Ion Exchange / instrumentation*
  • Conductometry / instrumentation*
  • DNA / analysis
  • DNA / chemistry
  • DNA / genetics*
  • DNA Mutational Analysis / instrumentation
  • Equipment Design
  • Equipment Failure Analysis
  • Membranes, Artificial*
  • Molecular Sequence Data
  • Nanopores / ultrastructure*
  • Nanotechnology / instrumentation
  • Nucleic Acids / analysis
  • Nucleic Acids / genetics*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Sequence Analysis, DNA / instrumentation*
  • Static Electricity

Substances

  • Membranes, Artificial
  • Nucleic Acids
  • DNA