Purpose: The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath compared with previously established percutaneous mechanical thrombectomy techniques in occluded hemodialysis grafts.
Materials and methods: One thousand three hundred five patients (767 women, 538 men; mean age, 61.04±13.09 years; mean graft age, 36.64±30.80 mo) with 2,531 episodes of hemodialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using criss-cross or apex puncture technique. Technical success rate, procedure time, complications and patency rates were analyzed.
Results: Technical success was achieved in 2,426 of 2,531 procedures (95.9%). Average procedure time of the intervention was 42.87±22.77 minutes. Primary patency rate was 61.9% at 3 mo, 41.2% at 6 mo and 19.6% at 1 year. Major complications occurred in 4.1% of cases (23 graft outflow rupture; 68 arterial emboli; 1 arterial dissection; 3 symptomatic pulmonary embolism; 1 stent migration) and minor complications occurred in 7.7% of cases (196 cases). These results were comparable to previously reported mechanical thrombectomy techniques in occluded hemodialysis grafts.
Conclusions: Percutaneous thromboaspiration of occluded hemodialysis grafts with a Desilets-Hoffman Sheath is an effective and safe method.