0.125 mm(3) spatial resolution steady-state MR angiography of the thighs with a blood pool contrast agent using the quadrature body coil only at 1.5 Tesla

J Magn Reson Imaging. 2014 Oct;40(4):996-1001. doi: 10.1002/jmri.24455. Epub 2014 Feb 6.

Abstract

Purpose: To implement and evaluate high spatial resolution three-dimensional MR contrast-enhanced angiography (3D-CEMRA) of the thighs using a blood pool contrast agent (BPCA) using the quadrature body coil only in patients with peripheral arterial occlusive disease (PAOD) in cases receiver coils cannot be used at 1.5 Tesla (T).

Materials and methods: Nineteen patients (mean age: 68.7 ± 11.2 years; range, 38-83 years) with known PAOD (Fontaine stages; III: 16, IV: 3) prospectively underwent 3D-CEMRA at 1.5T with a noninterpolated voxel size of 0.49 × 0.49 × 0.48 mm(3) . Digital subtraction angiography (DSA) was available for comparison in all patients. Two readers independently evaluated movement artifacts, overall image quality of 3D-CEMRA, and grade of stenosis as compared to DSA. SNR and CNR levels were quantified.

Results: The 3D-CEMRA was successfully completed in all patients. Patient movement artifacts that affected stenosis grading occurred in 3/38 thighs. Overall image quality was rated excellent in 15/38, good in 12/38, and diagnostic in 8/38 thighs. Stenosis grading matched with that in DSA in 35/38 thighs. High SNR and CNR were measured in all vessels.

Conclusion: The 0.125 mm(3) spatial resolution 3D-CEMRA of the thighs with a BPCA is feasible using a quadrature body coil exclusively with excellent image quality despite long acquisition times. J. Magn. Reson. Imaging 2014;40:996-1001. © 2014 Wiley Periodicals, Inc.

Keywords: blood pool contrast agent; high-spatial resolution MRA; peripheral arterial occlusive disease.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Arterial Occlusive Diseases / pathology
  • Arterial Occlusive Diseases / physiopathology*
  • Blood Flow Velocity / physiology
  • Contrast Media
  • Equipment Design
  • Equipment Failure Analysis
  • Feasibility Studies
  • Female
  • Gadolinium*
  • Humans
  • Image Enhancement / instrumentation*
  • Image Enhancement / methods
  • Imaging, Three-Dimensional / instrumentation
  • Imaging, Three-Dimensional / methods
  • Magnetic Resonance Angiography / instrumentation*
  • Magnetic Resonance Angiography / methods
  • Male
  • Middle Aged
  • Organometallic Compounds*
  • Peripheral Arterial Disease / pathology
  • Peripheral Arterial Disease / physiopathology*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Thigh / blood supply
  • Thigh / pathology
  • Thigh / physiopathology*

Substances

  • Contrast Media
  • Organometallic Compounds
  • Gadolinium
  • gadofosveset trisodium