Effects of impression levels and trays on the accuracy of impressions taken from angulated implants

Clin Oral Implants Res. 2015 Sep;26(9):1098-105. doi: 10.1111/clr.12410. Epub 2014 Jun 17.

Abstract

Background and purpose: It is crucial to keep the misfit of the abutment-fixture unit at the lowest possible rate. There are a few controversial studies on the accuracy of impression making of angulated implants, and much fewer (and controversial) studies on the abutment-level impression technique, which is a convenient and clinically favorable method. Besides, there are no studies on comparison of sectional vs. full-arch trays. We aimed to assess these.

Methods: A trapezoidal model with four angulated implants installed at 20° and 30° buccal tilts was fabricated. Forty impressions were taken from this model, with two groups of full-arch and sectional custom trays (n = 2 × 20), each divided into two subgroups of implant-level and abutment-level techniques (n = 2 × 2 × 10 in four subgroups). Absolute and non-absolute linear and angular impression errors were estimated by comparing the fabricated casts with the model, using a coordinate measuring machine. The effects of sectional/full-arch trays and abutment-level and fixture-level techniques on impression accuracies were analyzed using one- and two-way analyses of variance (ANOVA), Tukey, Mann-Whitney, and one-sample t-tests (α = 0.05, Mann-Whitney's α using the Bonferroni Bonferroni method).

Results: No significant differences between the absolute linear errors of the two trays (P = 0.100 [ANOVA]) and the two levels (P = 0.400 [ANOVA]) were observed. The assessment of absolute angular errors showed no significant differences (all P values ≥ 0.4 [ANOVA]). The difference between the linear errors in the full-arch vs. sectional trays was not significant in the fixture-level group (P = 0.290). However, in the abutment-level group, the linear error was significantly greater in the sectional tray compared to full-arch tray (P = 0.013, α = 0.025 [Mann-Whitney]).

Conclusions: Using sectional trays might not be advantageous over full-arch trays. Sectional trays are not recommended for taking abutment-level impressions. The abutment-level impression technique is as accurate as the studied fixture-level technique. Increasing the angle of implants' divergence from 40° to 60° might not usually lead to a significant increase in the errors, particularly when using abutment-level impressions.

Keywords: angulated dental implants; impression accuracy; impression levels (implant-level abutment-level); impression trays.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Analysis of Variance
  • Dental Abutments*
  • Dental Implants*
  • Dental Impression Technique*
  • Models, Dental

Substances

  • Dental Implants