Cerebral blood flow during submaximal and maximal dynamic exercise in humans

J Appl Physiol (1985). 1989 Aug;67(2):744-8. doi: 10.1152/jappl.1989.67.2.744.

Abstract

Cerebral blood flow (CBF) in humans was measured at rest and during dynamic exercise on a cycle ergometer corresponding to 56% (range 27-85) of maximal O2 uptake (VO2max). Exercise bouts were performed by 16 male and female subjects, lasted 15 min each, and were carried out in a semisupine position. CBF (133Xe clearance) was expressed as the initial slope index (ISI) and as the first compartment flow (F1). CBF at rest [ISI, 58 (range 45-73); F1, 76 (range 55-98) ml.100 g-1.min-1] increased during exercise [ISI to 79 (57-94) and F1 to 118 (75-164) ml.100 g-1.min-1, P less than 0.01]. CBF did not differ significantly between work loads from 32 (24-33) to 86% (74-96) of VO2max (n = 10). During exercise, mean arterial pressure increased from 84 (60-100) to 101 (78-124) Torr (P less than 0.01) and PCO2 remained unchanged [5.1 (4.6-5.6) vs. 5.4 (4.4-6.3) kPa, n = 6]. These results demonstrate a median increase of 31% (0-87) in CBF by ISI and a median increase of 58% (0-133) in CBF by F1 during dynamic exercise in humans.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Blood Flow Velocity
  • Blood Pressure
  • Carbon Dioxide
  • Cerebrovascular Circulation*
  • Exercise Test
  • Exercise*
  • Female
  • Heart Rate
  • Humans
  • Male
  • Oxygen Consumption
  • Partial Pressure
  • Respiration
  • Tidal Volume

Substances

  • Carbon Dioxide