44-h ambulatory blood pressure monitoring: revealing the true burden of hypertension in pediatric hemodialysis patients

Pediatr Nephrol. 2015 Apr;30(4):653-60. doi: 10.1007/s00467-014-2964-7. Epub 2014 Sep 26.

Abstract

Background: The blood pressure (BP) burden is high in pediatric hemodialysis (HD) patients and adversely affects prognosis. The aim of this study was to examine whether 44-h ambulatory BP monitoring (ABPM) provides additional relevant BP data compared with 24-h ABPM.

Methods: ABPM was initiated at the end of the mid-week dialysis run in 13 stable pediatric HD patients and continued until the next run for 44 h. Day 1 was defined as the initial 24-h ABPM and Day 2 as the time period after that until the next dialysis run. All patients had an echocardiogram to calculate the left ventricular mass index (LVMI).

Results: A higher percentage of patients were diagnosed with hypertension from the 44-h ABPM than from the 24-h ABPM. All BP indexes and loads (except nighttime diastolic load) were significantly higher on Day 2 than on Day 1. Patients with BP loads of ≥ 25 % on 44-h ABPM had significantly higher LVMI than those patients with normal BP loads. No such association was found with 24-h ABPM and LVMI. Higher interdialytic weight gain was associated with higher Day-2 nighttime systolic BP load.

Conclusions: The 44-h ABPM provides more information than the 24-h ABPM in terms of diagnosing and assessing the true burden of hypertension in pediatric HD patients. Elevated BP loads from 44-h ABPM correlate with a higher LVMI on the echocardiogram.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Blood Pressure / physiology*
  • Blood Pressure Monitoring, Ambulatory / methods*
  • Cross-Sectional Studies
  • Echocardiography
  • Female
  • Humans
  • Hypertension / physiopathology*
  • Hypertrophy, Left Ventricular / physiopathology
  • Male
  • Renal Dialysis*