Background: Because further treatment plans depends on lymph node (LN) status after neoadjuvant chemoradiation therapy (CRT), the accurate characterization of LN is important.
Purpose: To evaluate the diagnostic performance of apparent diffusion coefficient (ADC) for LN characterization after CRT and to compare the performance with that of LN size.
Material and methods: Fifty-three patients (36 men, 17 women; mean age, 58 years; age range, 34-79 years) who underwent CRT and subsequent surgery were included. All patients underwent 1.5-T magnetic resonance imaging (MRI). Each regional LN on post-CRT MRI was identified in consensus by two radiologists after reviewing the pre-CRT MRI. The ADC value and size in each LN was measured. To compare the mean ADC values and sizes of the metastatic and non-metastatic LNs after CRT, the t-test was used. To calculate the performance, a ROC curve analysis was performed. The histopathological examinations served as the reference standard.
Results: A total of 115 LNs (29 metastatic and 86 non-metastatic) were matched and analyzed. The mean ADC of the metastatic LNs was significantly higher than that of the non-metastatic LNs (1.36 ± 0.27 × 10(-3)mm(2)/s; 1.13 ± 0.23 × 10(-3)mm(2)/s, P < 0.0001). The mean size of the metastatic LNs was also significantly larger than that of the non-metastatic LNs (5.6 ± 3.1; 3.9 ± 1.2, P = 0.0078). There was no significant difference between the areas under the curve of the ADC and size (0.742 [95% CI, 0.652-0.819]; 0.680 [0.586-0.764], respectively, P = 0.4090).
Conclusion: The performance of ADC for LN characterization after CRT was comparable to that of LN size.
Keywords: Diffusion-weighted magnetic resonance imaging; apparent diffusion coefficient; lymph node; lymphatic metastasis; neoplasm; rectum.
© The Foundation Acta Radiologica 2014.