Stenting as a rescue treatment of a pulmonary artery false aneurysm caused by swan-ganz catheterization

Case Rep Pulmonol. 2014:2014:893647. doi: 10.1155/2014/893647. Epub 2014 Dec 28.

Abstract

Pulmonary vascular injury is a rare but life-threatening complication of Swan-Ganz catheterization. We report an 82-year old patient who underwent right heart catheterization by a balloon-tipped catheter because of suspected pulmonary hypertension. After deflation of the catheter in the wedge position, hemoptoe appeared associated with acute respiratory insufficiency requiring respiratory support by intubation and mechanical ventilation. Pulmonary angiography showed the formation of a false aneurysm of a segment artery of the left lower lobe. Immediate interventional therapy was performed by the implantation of two coated coronary stent grafts into the injured pulmonary artery thereby excluding the false aneurysm. Bleeding was stopped by this interventional approach while antegrade blood flow was maintained. Long term follow-up after 3 months showed an effective treatment with a completely thrombotic false aneurysm. However, despite oral anticoagulation and dual antiplatelet therapy, graft patency could not be achieved after 3 months. In summary, implantation of coated stents is a feasible and safe approach for the acute and long term treatment of potentially life-threatening condition of a pulmonary artery false aneurysm while treatment to achieve long term patency of the affected vessel still remains an issue to be resolved.