Reproducibility of MR-based liver fat quantification across field strength: Same-day comparison between 1.5T and 3T in obese subjects

J Magn Reson Imaging. 2015 Sep;42(3):811-7. doi: 10.1002/jmri.24842. Epub 2015 Jan 23.

Abstract

Purpose: To examine the reproducibility of quantitative magnetic resonance (MR) methods to estimate hepatic proton density fat-fraction (PDFF) at different magnetic field strengths.

Materials and methods: This Health Insurance Portability and Accountability Act (HIPAA)-compliant study was approved by the Institutional Review Board. Following informed consent, 25 severely obese subjects (mean body mass index [BMI]: 45 ± 4, range: 38-53 kg/m(2) ) were scanned at 1.5T and 3T on the same day. Two confounder-corrected multiecho chemical shift-encoded gradient-echo-based imaging methods were acquired to estimate PDFF over the entire liver: 3D complex-based (MRI-C) and 2D magnitude-based (MRI-M) MRI. Single-voxel MR spectroscopy (MRS) was performed in the right liver lobe. Using linear regression, pairwise comparisons of estimated PDFF were made between methods (MRI-C, MRI-M, MRS) at each field strength and for each method across field strengths.

Results: 1.5T vs. 3T regression analyses for MRI-C, MRI-M, and MRS PDFF measurements yielded R(2) values of 0.99, 0.97, and 0.90, respectively. The best-fit line was near unity (slope(m) = 1, intercept(b) = 0), indicating excellent agreement for each case: MRI-C (m = 0.92 [0.87, 0.99], b = 1.4 [0.7, 1.8]); MRI-M (m = 1.0 [0.90, 1.08], b = -1.4 [-2.4, -0.5]); MRS (m = 0.98 [0.82, 1.15], b = 1.2 [-0.2, 3.0]). Comparing MRI-C and MRI-M yielded an R(2) = 0.98 (m = 1.1 [1.02, 1.16], b = -1.8 [-2.8, -1.1]) at 1.5T, and R(2) = 0.99 (m = 0.98 [0.93, 1.03], b = 1.2 [0.7, 1.7]) at 3T.

Conclusion: This study demonstrates that PDFF estimation is reproducible across field strengths and across two confounder-corrected MR-based methods.

Keywords: chemical shift; fat quantification; liver; magnetic resonance imaging; obesity; proton density fat-fraction; reproducibility.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Adipose Tissue / pathology*
  • Adult
  • Body Mass Index
  • Echo-Planar Imaging
  • Female
  • Humans
  • Image Processing, Computer-Assisted
  • Imaging, Three-Dimensional
  • Liver / pathology
  • Magnetic Resonance Imaging*
  • Magnetic Resonance Spectroscopy
  • Male
  • Middle Aged
  • Non-alcoholic Fatty Liver Disease / pathology
  • Obesity / physiopathology*
  • Protons
  • Regression Analysis
  • Reproducibility of Results

Substances

  • Protons