Clinical Outcome of Patients Transplanted with Marginal Donor Lungs via Ex Vivo Lung Perfusion Compared to Standard Lung Transplantation

Transplantation. 2015 May;99(5):1078-83. doi: 10.1097/TP.0000000000000462.

Abstract

Background: Lung transplantation is limited by a scarcity of suitable donors resulting in high waiting list mortality. Ex vivo lung perfusion (EVLP) allows the evaluation and reconditioning of marginal donor lungs for use in transplantation. This study aimed to compare clinical outcome of patients transplanted with marginal organs by means of EVLP with a standard lung transplant cohort through a multicenter open trial.

Methods: Group 1 (n = 9) included patients transplanted using EVLP reconditioned marginal lungs. Group 2 (n = 46) consisted of date-matched patients transplanted using standard transplantation of acceptable lungs. The primary composite endpoint included acute rejection and infection at 12 months after transplantation.

Results: There was no significant difference in the overall incidence of acute rejection (P = 0.754) and the number of treated infection episodes (proven/probable pneumonia; P = 0.857/0.368 and proven/probable tracheobronchitis; P = 0.226/0.529) up to 12 months after transplantation, between group 1 and group 2. Additionally, there was no significant difference in early clinical outcome, including intensive care unit stay, hospital stay, and 1 year mortality between the two groups (P = 0.338, P = 0.112 and P = 0.372, respectively).

Discussion: This multicenter study demonstrates that EVLP is associated with no adverse effect on clinical outcome, including the incidence of acute rejection and infection after lung transplantation.

Publication types

  • Comparative Study
  • Multicenter Study

MeSH terms

  • Adult
  • Aged
  • Female
  • Graft Rejection / epidemiology
  • Humans
  • Lung / blood supply*
  • Lung Transplantation / adverse effects
  • Lung Transplantation / methods*
  • Male
  • Middle Aged
  • Perfusion
  • Tissue Donors*