[Development of a diagnostic test system for detecting soluble staphylococcal antigens by an immunoenzyme method]

Zh Mikrobiol Epidemiol Immunobiol. 1985 Jan:(1):45-8.
[Article in Russian]

Abstract

ELISA is used for detecting the soluble staphylococcal antigen in patients with purulent septic infections. The optimum conditions for the assay have been established: the dose of staphylococcal gamma globulin for plate sensitization should be 5.0-10.0 micrograms/ml, the pH of the buffer solution 9.6-10.0, the time and temperature of incubation 18-20 hours at 4 degrees C or 5 hours at 37 degrees C. The possibility of using plates manufactured in the USSR has been shown. The sensitivity of the above diagnostic test system is 0.005 microgram/ml.