Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections

Radiother Oncol. 2015 Apr;115(1):22-9. doi: 10.1016/j.radonc.2015.02.022. Epub 2015 Mar 26.

Abstract

Background and purpose: A technique has been previously reported to estimate high-quality 4D-CBCT using prior information and limited-angle projections. This study is to investigate its clinical feasibility through both phantom and patient studies.

Materials and methods: The new technique used to estimate 4D-CBCT is called MMFD-NCC. It is based on the previously reported motion modeling and free-form deformation (MMFD) method, with the introduction of normalized-cross-correlation (NCC) as a new similarity metric. The clinical feasibility of this technique was evaluated by assessing the accuracy of estimated anatomical structures in comparison to those in the 'ground-truth' reference 4D-CBCTs, using data obtained from a physical phantom and three lung cancer patients. Both volume percentage error (VPE) and center-of-mass error (COME) of the estimated tumor volume were used as the evaluation metrics.

Results: The average VPE/COME of the tumor in the prior image was 257.1%/10.1 mm for the phantom study and 55.6%/3.8 mm for the patient study. Using only orthogonal-view 30° projections, the MMFD-NCC has reduced the corresponding values to 7.7%/1.2 mm and 9.6%/1.1 mm, respectively.

Conclusion: The MMFD-NCC technique is able to estimate 4D-CBCT images with geometrical accuracy of the tumor within 10% VPE and 2 mm COME, which can be used to improve the localization accuracy of radiotherapy.

Keywords: 4D-CBCT; Free-form deformation; Image estimation; Motion modeling.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cone-Beam Computed Tomography / instrumentation
  • Cone-Beam Computed Tomography / methods*
  • Four-Dimensional Computed Tomography / instrumentation
  • Four-Dimensional Computed Tomography / methods*
  • Humans
  • Lung Neoplasms / radiotherapy*
  • Motion
  • Phantoms, Imaging