Dosimetric evaluation of whole-breast radiation therapy: clinical experience

Med Dosim. 2015 Winter;40(4):355-65. doi: 10.1016/j.meddos.2015.05.001. Epub 2015 Jun 26.

Abstract

Radiation therapy of the intact breast is the standard therapy for preventing local recurrence of early-stage breast cancer following breast conservation surgery. To improve patient standard of care, there is a need to define a consistent and transparent treatment path for all patients that reduces significance variations in the acceptability of treatment plans. There is lack of consistency among institutions or individuals about what is considered an acceptable treatment plan: target coverage vis-à-vis dose to organs at risk (OAR). Clinical trials usually resolve these issues, as the criteria for an acceptable plan within the trial (target coverage and doses to OAR) are well defined. We developed an institutional criterion for accepting breast treatment plans in 2006 after analyzing treatment data of approximately 200 patients. The purpose of this article is to report on the dosimetric review of 623 patients treated in the last 18 months to evaluate the effectiveness of the previously developed plan acceptability criteria and any possible changes necessary to further improve patient care. The mean patient age is 61.6 years (range: 25.2 to 93.0 years). The mean breast separation for all the patients is 21.0cm (range: 12.4 to 34.9cm), and the mean planning target volume (PTV_eval) (breast volume for evaluation) is 884.0cm(3) (range: 73.6 to 3684.6cm(3)). Overall, 314 (50.4%) patients had the disease in the left breast and 309 (49.6%) had it in the right breast. A total of 147 (23.6%) patients were treated using the deep inspiration breath-hold (DIBH) technique. The mean normalized PTV_eval receiving at least 92% (V92% PD) and 95% (V95% PD) of the prescribed dose (PD) are more than 99% and 97%, respectively, for all patients. The mean normalized PTV_eval receiving at least 105% (V105% PD) of the PD is less than 1% for all groups. The mean homogeneity index (HI), uniformity index (UI), and conformity index (CI) for the PTV_eval are 0.09 (range: 0.05 to 0.15), 1.07 (range: 0.46 to 1.11), and 0.98 (range: 0.92 to 1.0), respectively. Our data confirm the significant advantage of using DIBH to reduce heart dose when compared with the free-breathing technique. The p values analyses of the results for the V5Gy, V10Gy, V15Gy, V20Gy, and V30Gy for the heart comparing DIBH and free-breathing techniques are well less than 0.05 (i.e., p < 0.05). However, similar analyses for the lung give values greater than 0.05 (i.e., p > 0.05), indicating that there is no significant difference in lung dose comparing the 2 treatment techniques.

Keywords: Breast treatment; Breath-hold technique; Dose-volume histogram; Free-breathing technique; Hybrid treatment; Radiation therapy.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Breast Neoplasms / radiotherapy*
  • Female
  • Heart
  • Humans
  • Lung
  • Middle Aged
  • Radiotherapy Planning, Computer-Assisted / statistics & numerical data*
  • Retrospective Studies