Mid-term clinical outcomes of ABSORB bioresorbable vascular scaffold implantation in a real-world population: A single-center experience

Cardiovasc Revasc Med. 2015 Dec;16(8):461-4. doi: 10.1016/j.carrev.2015.08.003. Epub 2015 Aug 15.

Abstract

Background: Available data on the use of the ABSORB bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA) in real-world patients is limited. The aim of this study was to assess the mid-term clinical outcomes in a real-world population treated with ABSORB BVS.

Methods and materials: We retrospectively evaluated all patients treated with ABSORB at Papworth Hospital, Papworth Everard, UK between July 2012 and July 2014. A total of 108 patients (126 lesions) were identified. Clinical follow-up was performed on all subjects by clinic visit or telephone interview.

Results: Most patients were male (91.7%) with a relative high incidence of previous myocardial infarction (MI) (40.7%). Clinical presentation was equally divided between stable angina and acute coronary syndrome (ACS) (51.8% vs. 48.2%, p=0.59). Of the ACS patients, 26.9% presented with ST-elevation myocardial MI. Intravascular imaging was used in all cases. Predilatation (92.9%) and postdilatation (82.5%) were frequently performed. Major adverse cardiac event (MACE) rates defined as the composite of all-cause death, follow-up MI and target vessel revascularization were 2.5% at 6-month and 4.5% at 1-year. The 1-year target lesion failure rate, defined as the composite of cardiac death, target-vessel MI and target lesion revascularization was 1.9%. There was 1 case of subacute stent thrombosis.

Conclusions: The use of ABSORB BVS in real-world patients appears to be associated with good mid-term clinical outcomes when guided by intravascular imaging. Larger studies are required to evaluate further the role of BVS in routine clinical practice and examine how this compares to metallic devices.

Summary: Available data on the use of the ABSORB BVS in real-world patients is limited. We retrospectively evaluated all patients treated with ABSORB BVS between July 2012 and July 2014. A total of 108 patients (126 lesions) were identified. Clinical presentation was equally divided between stable angina and acute coronary syndrome (51.8% vs. 48.2%, p=0.59). Predilatation (92.9%) and postdilatation (82.5%) were frequently performed. Estimated MACE rates at 6-month and 1-year were 2.5% and 4.5% respectively, with a 1-year TLF rate of 1.9%. These results suggest that the use of ABSORB BVS use in the real-world is associated with good mid-term clinical outcomes when guided by intravascular imaging.

Keywords: Bioresorbable vascular scaffold; Clinical outcomes; Drug-eluting stent; Real-world.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Absorbable Implants*
  • Chi-Square Distribution
  • Child
  • Cohort Studies
  • Coronary Angiography / methods
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Databases, Factual
  • Drug-Eluting Stents*
  • Female
  • Follow-Up Studies
  • Hospitals, University
  • Humans
  • Kaplan-Meier Estimate
  • Length of Stay
  • Male
  • Middle Aged
  • Percutaneous Coronary Intervention / methods*
  • Percutaneous Coronary Intervention / mortality
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Severity of Illness Index
  • Statistics, Nonparametric
  • Stents
  • Survival Rate
  • Time Factors
  • Treatment Outcome
  • United Kingdom
  • Vascular Patency / physiology