Objective: To explore the efficiency, cost, and time for examination of one-stop-shop gadoxetic acid disodium (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) in preoperative evaluation for parent donors by comparing with multidetector computer tomography combined with conventional MR cholangiopancreatography (MDCT-MRCP).
Materials and methods: Forty parent donors were evaluated with MDCT-MRCP, and the other 40 sex-, age-, and weight-matched donors with Gd-EOB-DTPA-enhanced MRI. Anatomical variations and graft volume determined by pre- and intra-operative findings, costs and time for imaging were recorded. Image quality was ranked on a 4-point scale and compared between both groups.
Results: Gd-EOB-DTPA-enhanced MRI provided better image quality than MDCT-MRCP for the depiction of portal veins and bile ducts by both reviewers (p < 0.05), hepatic veins by one reviewer (p < 0.05), rather hepatic arteries by both reviewers (p < 0.01). Sixty-nine living donors proceeded to liver donation with all anatomical findings accurately confirmed by intra-operative findings. The "in-room" time of Gd-EOB-DTPA-enhanced MRI was 12 min longer than MDCT-MRCP. Gd-EOB-DTPA-enhanced MRI was cheaper than MDCT-MRCP (US$519.72 vs. US$631.85).
Conclusion: One-stop-shop Gd-EOB-DTPA-enhanced MRI has similar diagnostic accuracy as MDCT-MRCP and can provide additional benefit in terms of costs and convenience in preoperative evaluation for parent donors.