Differential Effects of Intraoperative Positive End-expiratory Pressure (PEEP) on Respiratory Outcome in Major Abdominal Surgery Versus Craniotomy

Ann Surg. 2016 Aug;264(2):362-369. doi: 10.1097/SLA.0000000000001499.

Abstract

Objectives: In this study, we examined whether (1) positive end-expiratory pressure (PEEP) has a protective effect on the risk of major postoperative respiratory complications in a cohort of patients undergoing major abdominal surgeries and craniotomies, and (2) the effect of PEEP is differed by surgery type.

Background: Protective mechanical ventilation with lower tidal volumes and PEEP reduces compounded postoperative complications after abdominal surgery. However, data regarding the use of intraoperative PEEP is conflicting.

Methods: In this observational study, we included 5915 major abdominal surgery patients and 5063 craniotomy patients. Analysis was performed using multivariable logistic regression. The primary outcome was a composite of major postoperative respiratory complications (respiratory failure, reintubation, pulmonary edema, and pneumonia) within 3 days of surgery.

Results: Within the entire study population (major abdominal surgeries and craniotomies), we found an association between application of PEEP ≥5 cmH2O and a decreased risk of postoperative respiratory complications compared with PEEP <5 cmH2O. Application of PEEP >5 cmH2O was associated with a significant lower odds of respiratory complications in patients undergoing major abdominal surgery (odds ratio 0.53, 95% confidence interval 0.39 - 0.72), effects that translated to deceased hospital length of stay [median hospital length of stay : 6 days (4-9 days), incidence rate ratios for each additional day: 0.91 (0.84 - 0.98)], whereas PEEP >5 cmH2O was not significantly associated with reduced odds of respiratory complications or hospital length of stay in patients undergoing craniotomy.

Conclusions: The protective effects of PEEP are procedure specific with meaningful effects observed in patients undergoing major abdominal surgery. Our data suggest that default mechanical ventilator settings should include PEEP of 5-10 cmH2O during major abdominal surgery.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Abdomen / surgery*
  • Adult
  • Aged
  • Cohort Studies
  • Craniotomy / adverse effects*
  • Female
  • Humans
  • Intraoperative Care*
  • Male
  • Middle Aged
  • Positive-Pressure Respiration*
  • Postoperative Complications / prevention & control*
  • Respiration Disorders / prevention & control*
  • Tidal Volume