Iodine concentration as a perfusion surrogate marker in oncology: Further elucidation of the underlying mechanisms using Volume Perfusion CT with 80 kVp

Eur Radiol. 2016 Sep;26(9):2929-36. doi: 10.1007/s00330-015-4154-9. Epub 2015 Dec 17.

Abstract

Objectives: To assess the value of iodine concentration (IC) in computed tomography data acquired with 80 kVp, as a surrogate for perfusion imaging in hepatocellular carcinoma (HCC) and lymphoma by comparing iodine related attenuation (IRA) with quantitative Volume Perfusion CT (VPCT)-parameters.

Methods: VPCT-parameters were compared with intra-tumoral IC at 5 time points after the aortic peak enhancement (APE) with a temporal resolution of 3.5 sec in untreated 30 HCC and 30 lymphoma patients.

Results: Intra-tumoral perfusion parameters for HCC showed a blood flow (BF) of 52.7 ± 17.0 mL/100 mL/min, blood volume (BV) 12.6 ± 4.3 mL/100 mL, arterial liver perfusion (ALP) 44.4 ± 12.8 mL/100 mL/min. Lesion IC 7 sec after APE was 133.4 ± 57.3 mg/100 mL. Lymphoma showed a BF of 36.8 ± 13.4 mL/100 mL/min, BV of 8.8 ± 2.8 mL/100 mL and IC of 118.2 ± 64.5 mg/100 mL 3.5 sec after APE. Strongest correlations exist for VPCT-derived BF and ALP with IC in HCC 7 sec after APE (r = 0.71 and r = 0.84) and 3.5 sec after APE in lymphoma lesions (r = 0.77). Significant correlations are also present for BV (r = 0.60 and r = 0.65 for HCC and lymphoma, respectively).

Conclusions: We identified a good, time-dependent agreement between VPCT-derived flow values and IC in HCC and lymphoma. Thus, CT-derived ICs 7 sec after APE in HCC and 3.5 sec in lymphoma may be used as surrogate imaging biomarkers for tumor perfusion with 80 kVp.

Key points: • Iodine concentration derived from low kVp CT is regarded as perfusion surrogate • Correlation with Perfusion CT was performed to elucidate timing and histology dependencies • Highest correlation was present 7 sec after aortic peak enhancement in hepatocellular carcinoma • In lymphoma, highest correlation was calculated 3.5 sec after aortic peak enhancement • With these results, further optimization of Dual energy CT protocols is possible.

Keywords: Contrast media; Hepatocellular carcinoma; Lymphoma; Multislice computed tomography; Perfusion imaging.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Biomarkers
  • Blood Volume
  • Carcinoma, Hepatocellular / diagnostic imaging*
  • Cone-Beam Computed Tomography / methods*
  • Female
  • Humans
  • Iodine / pharmacokinetics*
  • Liver / diagnostic imaging
  • Liver Neoplasms / diagnostic imaging*
  • Lymphoma / diagnostic imaging*
  • Male
  • Middle Aged
  • Perfusion Imaging / methods*
  • Prospective Studies
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • Biomarkers
  • Iodine