Transcatheter valve-in-valve implantation for failed mitral prosthesis: the first experience in Japan

Cardiovasc Interv Ther. 2017 Jan;32(1):82-86. doi: 10.1007/s12928-015-0374-9. Epub 2015 Dec 28.

Abstract

An 82-year-old woman had a history of mitral valve replacement with a 25-mm MOSAIC (Medtronic, USA) for severe mitral regurgitation (MR) 8 years previously. Recently, she developed heart failure due to MR secondary to prosthetic valve failure. She underwent transcatheter valve-in-valve implantation with a 23-mm SAPIEN XT (Edwards Lifesciences, USA) to the prosthetic mitral valve by transapical approach. To our knowledge, this is the first reported case of transcatheter valve implantation for failed mitral prosthetic valve using valve-in-valve technique in Japan.

Keywords: Mitral valve replacement; Transcatheter aortic valve replacement (TAVR); Valve-in-valve.

Publication types

  • Case Reports
  • Video-Audio Media

MeSH terms

  • Aged, 80 and over
  • Echocardiography
  • Female
  • Heart Valve Prosthesis / adverse effects*
  • Heart Valve Prosthesis Implantation / methods*
  • Humans
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / surgery*
  • Mitral Valve Insufficiency / diagnosis
  • Mitral Valve Insufficiency / surgery*
  • Prosthesis Design
  • Prosthesis Failure
  • Reoperation