Radiopharmacological investigations of [(18)F]NS14490 have proven that this radiotracer could be a potential PET radiotracer for imaging of alpha7 nicotinic acetylcholine receptor particularly with regard to vulnerable plaques of diseased vessels. For further optimisation of the previously automated one-pot radiosynthesis of [(18)F]NS14490 using a tosylate precursor, precursors with other leaving groups (nosylate and mosylate) were synthesized and compared with the tosylate with respect to their reactivities towards [(18)F]fluoride. The use of these different precursors resulted in comparable labelling yields of [(18)F]NS14490. A novel mosylate precursor was synthesized and evaluated, which has revealed a higher stability during a storage period of five months compared to the corresponding tosylate and nosylate.
Keywords: Alpha7 nAChR ligand; Mosylate; Nosylate; PET; Reactivity of precursor; Synthesis of precursor; Tosylate.