Hemothorax caused by replacement of hemodialysis catheter: A case report

Hemodial Int. 2016 Oct;20(4):E7-E10. doi: 10.1111/hdi.12428. Epub 2016 May 16.

Abstract

Central venous catheters (CVC) are widely used in clinics to gain vascular access, but the risk and prevalence of catheter-related complications remains a serious issue. We report a long-term dialysis catheter accidentally inserted into the mediastinum via the right jugular vein in a hemodialysis patient. We also review complications associated with vascular catheterization and propose immediate therapeutic interventions for such cases.

Keywords: Hemodialysis catheter; complication; hemothorax.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Catheterization, Central Venous / adverse effects*
  • Catheters, Indwelling / adverse effects*
  • Central Venous Catheters / adverse effects
  • Female
  • Hemothorax / etiology*
  • Humans
  • Jugular Veins