Objectives: To evaluate the feasibility of a double-acquisition coronary CT angiography (CCTA) protocol in the presence and absence of an intravenous (IV) vasodilator infusion for detecting vasospastic angina.
Methods: Twenty patients with a high clinical probability of vasospastic angina were enrolled. All subjects underwent baseline CCTA without a vasodilator in the early morning followed by a catheterized coronary angiography with ergonovine provocation test. Within 3 days, all subjects underwent repeat CCTA during a continuous IV infusion of nitrate. Vasospastic angina as detected by CCTA was defined as significant stenosis (≥50 %) with negative remodelling without definite plaques or diffuse small diameter (<2 mm) of a major coronary artery with a beaded appearance on baseline CT that completely dilated on IV nitrate CT. The CCTA results were compared to the catheterized ergonovine provocation test as the reference standard.
Results: Among 20 patients, the catheterized ergonovine provocation test detected vasospasm in 15 patients. The sensitivity, specificity, positive predictive value and negative predictive value of CCTA in a per-patient-based analysis were 73, 100, 100 and 56 %, respectively.
Conclusions: Double-acquisition CCTA in the presence and absence of IV infusion of nitrate allows noninvasive detection of vasospastic angina with moderate sensitivity and high specificity.
Key points: • Limited data exist regarding the efficacy of CCTA in detecting vasospastic angina. • We propose a double-acquisition CCTA protocol with and without IV nitrate injections. • This protocol provides 100% specificity and moderate sensitivity (73%) in spasm detection.
Keywords: Angina pectoris, variant; Computed tomography; Coronary angiography; Coronary vessels; Spasm.