SNR efficiency of combined bipolar gradient echoes: Comparison of three-dimensional FLASH, MPRAGE, and multiparameter mapping with VFA-FLASH and MP2RAGE

Magn Reson Med. 2017 Jun;77(6):2186-2202. doi: 10.1002/mrm.26306. Epub 2016 Jul 15.

Abstract

Purpose: High-bandwidth bipolar multiecho gradient echo sequences are increasingly popular in structural brain imaging because of reduced water-fat shifts, lower susceptibility effects, and improved signal-to-noise ratio (SNR) efficiency. In this study, we investigated the performance of three three-dimensional multiecho sequences (MPRAGE, MP2RAGE, and FLASH) with scan times < 9 min and 1-mm isotropic resolution against their single-echo, low-bandwidth counterparts at 3T. We also compared the performance of multiparameter mapping (PD, T1 , and T2*) with bipolar multiecho MP2RAGE versus the variable flip angle technique with multiecho FLASH (VFA-FLASH).

Methods: Multiecho sequences were optimized to yield equivalent contrast and improved SNR compared with their single-echo counterparts. Theoretical SNR gains were verified with measurements in a multilayered phantom. Robust image processing pipelines extracted PD, T1 , and T2* maps from MP2RAGE or VFA-FLASH, and the corresponding SNR was measured with varying SENSE accelerations (R = 1-5) and number of echoes (N = 1-12). All sequences were tested on four healthy volunteers.

Results: Multiecho sequences achieved SNR gains of 1.3-1.6 over single-echo sequences. MP2RAGE yielded comparable T1 -to-noise ratio to VFA-FLASH, but significantly lower SNR (<50%) in PD and T2* maps. Measured SNR gains agreed with the theoretical predictions for SENSE accelerations ≤3.

Conclusion: Multiecho sequences achieve higher SNR efficiency over conventional single-echo sequences, despite three-fold higher sampling bandwidths. VFA-FLASH surpasses MP2RAGE in its ability to map three parameters with high SNR and 1-mm isotropic resolution in a clinically relevant scan time (∼8:30 min), whereas MP2RAGE yields lower intersubject variability in T1 . Magn Reson Med 77:2186-2202, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

Keywords: T2*; FLASH; MP2RAGE; MPRAGE; SNR efficiency; T1; Variable Flip Angle; bipolar echoes; high resolution brain MRI; multiparameter mapping; proton density.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Algorithms*
  • Brain / anatomy & histology*
  • Humans
  • Image Enhancement / methods*
  • Image Interpretation, Computer-Assisted / methods*
  • Magnetic Resonance Imaging / methods*
  • Phantoms, Imaging
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Signal Processing, Computer-Assisted*
  • Signal-To-Noise Ratio