Modified Subtraction Coronary CT Angiography Method for Patients Unable to Perform Long Breath-Holds: A Preliminary Study

Acad Radiol. 2016 Sep;23(9):1170-5. doi: 10.1016/j.acra.2016.04.012. Epub 2016 Jul 15.

Abstract

Rationale and objectives: Severe calcifications of the coronary arteries are still a major challenge in coronary computed tomography (CT) angiography (CCTA). Subtraction CCTA using a 320-detector row CT scanner has recently been introduced for patients with severe calcifications. However, the conventional subtraction CCTA method requires a long breath-holding time of approximately 20-40 seconds. This is a major problem in clinical practice because many patients may not be able to perform such a long breath-hold. We explored a modified subtraction CCTA method with a short breath-holding time to overcome this problem.

Materials and methods: This study was approved by our institutional review board, and all patients gave written informed consent. A total of 12 patients with a coronary calcium score of >400 were enrolled in this study. All patients were unable to hold their breath for more than 20 seconds. Modified subtraction CCTA was performed using the bolus-tracking method. The acquisition protocol was adjusted so that the mask scan was acquired 10 seconds after the postcontrast scan during a single breath-hold. The subtraction image was obtained by subtracting the mask image data from the postcontrast image data. The breath-holding times were recorded. Enhancement of the coronary arteries in the subtraction images was assessed. Subjective image quality was evaluated in a total of 32 segments using a 4-point scale.

Results: The mean breath-holding time was 12.8 ± 0.8 seconds (range, 12-14 seconds). The average CT number in the coronary arteries was 288.6 ± 80.5 Hounsfield units (HU) in the subtraction images. Average image quality was significantly increased from 2.1 ± 0.9 with conventional CCTA to 3.1 ± 0.7 with subtraction CCTA (P < 0.001). With subtraction CCTA, the number of non-diagnostic segments was significantly reduced from 53% to 19% (P = 0.001).

Conclusions: This preliminary study has shown that our modified subtraction CCTA method allows the breath-holding time to be shortened to <15 seconds. This may substantially improve the success rate of subtraction CCTA by reducing artifacts and allowing this technique to be applied to patients who are unable to perform a long breath-hold.

Keywords: Computed tomography; coronary CT angiography; coronary artery calcification; subtraction.

MeSH terms

  • Aged
  • Artifacts
  • Breath Holding*
  • Computed Tomography Angiography / methods*
  • Coronary Angiography / methods*
  • Coronary Vessels / diagnostic imaging
  • Female
  • Humans
  • Male
  • Reproducibility of Results
  • Subtraction Technique*