A Population Pharmacokinetic Model for 51Cr EDTA to Estimate Renal Function

Clin Pharmacokinet. 2017 Jun;56(6):671-678. doi: 10.1007/s40262-016-0489-x.

Abstract

Background and objectives: 51Cr EDTA clearance (CL) from plasma is used to estimate glomerular filtration rate (GFR). We propose that current methods for analysing the raw 51Cr EDTA measurements over-simplifies the disposition of 51Cr EDTA and therefore could produce biased GFR estimates. The aim of this study was to develop a population pharmacokinetic model for 51Cr EDTA disposition and to compare model-predicted GFR to other methods of estimating renal function.

Patients and methods: Data from 40 individuals who received ~7.4 MBq of 51Cr EDTA, as an intravenous bolus, were available for analysis. Plasma radioactivity (counts/min) was measured from timed collection points at 2, 4, 6 and 24 h after the dose. A population analysis was conducted using NONMEM® version 7.2. Model-predicted GFR was compared with other methods for estimating renal function using mean prediction error (MPE).

Results: A two-compartment pharmacokinetic model with first-order elimination best fit the data. Compared with the model predictions, creatinine CL from 24 h urine data was unbiased. The commonly used 'slope-intercept' method for estimating isotopic GFR was positively biased compared with the model (MPE 15.5 mL/min/1.73 m2 [95% confidence interval {CI} 8.9-22.2]. The Cockcroft Gault, Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-Epi) equations led to negatively biased GFR estimates (MPE -19.0 [95% CI -25.4 to -12.7], -20.1 [95% CI -27.2 to -13.1] and -16.5 [95% CI -22.2 to -10.1] mL/min/1.73 m2, respectively).

Conclusions: The biased GFR estimates were most obvious in patients with relatively normal renal function. This may lead to inaccurate dosing in patients who are receiving drugs with a narrow therapeutic range where dosing is adjusted according to GFR estimates (e.g. carboplatin).

Study registration: The study is registered with the Australian New Zealand Clinical Trials Registry (ANZCTR), number: ACTRN 12611000035921.

Publication types

  • Controlled Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Chromium Radioisotopes
  • Edetic Acid / blood
  • Edetic Acid / pharmacokinetics*
  • Female
  • Glomerular Filtration Rate
  • Humans
  • Kidney / physiology*
  • Kidney Diseases / blood
  • Kidney Diseases / physiopathology
  • Male
  • Models, Biological*
  • Young Adult

Substances

  • Chromium Radioisotopes
  • Edetic Acid