The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups

Hip Int. 2017 Jul 25;27(4):368-372. doi: 10.5301/hipint.5000469. Epub 2017 Jan 20.

Abstract

Background: The RM Pressfit vitamys is a titanium particle-coated monoblock cup with vitamin E stabilised highly cross-linked polyethylene. Initial fixation is achieved via press-fit with subsequent stability by bone on-growth. This is the first study to report the 5-year results of this design.

Methods: We performed a prospective cohort study according to STROBE guidelines of 100 consecutive total hip replacements (THRs) in 92 patients all with ceramic heads. Demographic data, pre/postoperative visual analogue scale (VAS) for pain and satisfaction, Harris Hip Scores (HHS) and complications were recorded. Radiographic analysis of osteolysis and loosening was complemented by EBRA (Einzel-Bild-Röntgen-Analyse) evaluation of cup movement.

Results: Our cohort comprised 48 women (mean age 67; SD 10.4) and 44 men (mean age 69; SD 7.8). The mean body mass index was 27 kg/m2 (SD 4.6). Surgical indications were osteoarthritis 96%, avascular necrosis 3% and fracture 1%. 82% had a direct anterior approach, 15% anterolateral and 3% trans-gluteal. 4 surgeons were involved. 1 cup was repositioned and fixed with screws within a week of index surgery. There were 2 intraoperative femoral fractures, 3 haematomata with 1 requiring drainage and 1 deep infection settling with an open washout and modular exchange. Mean VAS satisfaction increased from 3.8 (SD 2.0) to 8.8 at 6 weeks (SD 1.4) and 9.5 (SD 1.3) at 5 years. The HHS functional scores were 58.9 (SD 13.2) preoperatively and 94.6 (SD 6.6) at 5 years. Radiographic analysis showed neither progressive radiolucency nor osteolysis. Mean migration was 1.5 mm after 5 years.

Conclusions: Mid-term results of the RM Pressfit vitamys cup are encouraging.

Publication types

  • Evaluation Study

MeSH terms

  • Acetabulum / surgery
  • Aged
  • Arthroplasty, Replacement, Hip / methods*
  • Coated Materials, Biocompatible
  • Cohort Studies
  • Female
  • Femur Head Necrosis / diagnostic imaging
  • Femur Head Necrosis / surgery
  • Follow-Up Studies
  • Hip Fractures / diagnostic imaging
  • Hip Fractures / surgery
  • Hip Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Osteoarthritis, Hip / diagnostic imaging
  • Osteoarthritis, Hip / surgery
  • Prospective Studies
  • Prosthesis Design / methods*
  • Prosthesis Failure
  • Risk Assessment
  • Switzerland
  • Time Factors
  • Titanium
  • Vitamin E / pharmacology*

Substances

  • Coated Materials, Biocompatible
  • Vitamin E
  • Titanium